User Contributed MET/CAL PROCEDURE ============================================================================= INSTRUMENT: HP 6218A:DC Power Supply DATE: 23-Feb-96 AUTHOR: User Contributed REVISION: 0 ADJUSTMENT THRESHOLD: 100% NUMBER OF TESTS: 10 NUMBER OF LINES: 143 CONFIGURATION: Datron 1281 STANDARD: DTB Metered Variac STANDARD: Clarostat 240-C STANDARD: EPC HS 5-500 ============================================================================= STEP FSC RANGE NOMINAL TOLERANCE MOD1 MOD2 3 4 CON 1.001 IEEE [@1281]*RST 1.002 ASK+ X 1.003 ASK- P F 1.004 HEAD ÍÍ INITIAL CONDITIONS ÍÍ 1.005 DISP The following test equipment is required: 1.005 DISP 1. Metered vaiac DTB # 2-172 1.005 DISP 2. Clarostat 240-C Power Resistor 1.005 DISP 3. EPC HS 5-500 5 Amp Shunt DTB # 14-107 1.006 DISP Set the UUT front panel controls as follows: 1.006 DISP POWER ON/OFF ....................................... OFF 1.006 DISP VOLTAGE and VERNIER .......................... fully CCW 1.006 DISP CURRENT and VERNIER .......................... fully CCW 1.006 DISP METER SELECTION switch ........................... VOLTS 1.007 DISP ÿ Connect the UUT and the 1281 as follows: 1.007 DISP ÿ[27][91]1m 6218A TO 1281[27][91]m 1.007 DISP ÿ OUTPUT + ÄÄÄÄÄÄÄÄÄÄÄÄ> INPUT-HI 1.007 DISP ÿ OUTPUT - ÄÄÄÄÄÄÄÄÄÄÄÄ> INPUT-LO 1.008 DISP Connect the EPC HS 5-500 5 Amp Shunt in series 1.008 DISP with the UUT and 240-C as follows: 1.008 DISP 1.008 DISP ÿ [27][91]1m 6218A TO SHUNT 1.008 DISP ÿ OUTPUT +20V ÄÄÄÄÄÄÄÄÄ> Shunt Right Terminal 1.008 DISP 1.008 DISP ÿ [27][91]1m SHUNT TO 240-C 1.008 DISP ÿ Shunt Left Terminal ÄÄÄÄÄÄÄÄÄ> INPUT (+) 1.009 DISP ÿ Connect the UUT and the 240-C as follows: 1.009 DISP ÿ[27][91]1m 6218A TO 240-C[27][91]m 1.009 DISP ÿ OUTPUT- COM ÄÄÄÄÄÄÄÄÄÄÄÄ> INPUT (-) 1.010 DISP Connect the 1281 HI and LO inputs accross the shunt 1.010 DISP as follows: 1.010 DISP ÿ [27][91]1m 1281 TO SHUNT 1.010 DISP ÿ CH A INPUT HI ÄÄÄÄÄÄÄÄÄ> RIGHT SHUNT METER TERMINAL 1.010 DISP ÿ CH A INPUT LO ÄÄÄÄÄÄÄÄÄ> LEFT SHUNT METER TERMINAL 1.011 DISP Set the 240-C decade switches to 9,9,9,9,9,9. 1.012 DISP Connect UUT AC line cord to Metered Variac. 1.013 DISP Set the UUT POWER switch to the ON position. 1.014 HEAD {} 1.015 HEAD {ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»} 1.016 HEAD {º METER ACCURACY TEST º} 1.017 HEAD {ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ} 1.018 HEAD {}ÍÍ METER ACCURACY TEST ÍÍ 1.019 STD DTB Metered Variac 1.020 JMP 2.001 1.021 EVAL 2.001 DISP Set the UUT front panel controls as follows: 2.001 DISP CURRENT and VERNIER ........................... fully CW 2.002 DISP Set UUT VOLTAGE controls for a UUT reading of exactly 2.002 DISP 50 Volts. 2.003 IEEE [@1281] DCV AUTO 2.004 IEEE [@1281] [D3000]RDG?[I] 2.005 ACC 200 50.000V 10P% 0.2P/ 2.006 MEME 2.007 MEMC V 3% 0.000U 3.001 STD Clarostat 240-C 3.002 DISP Set the UUT front panel controls as follows: 3.002 DISP METER SELECTION switch .............................. mA 3.003 STD EPC HS 5-500 3.004 MEMI Use keyboard to enter actual shunt value in Ohms: 3.005 MATH M[1] = MEM 3.006 DISP Adjust the 240-C decade switches for a UUT meter reading 3.006 DISP of exactly 200mA. 3.007 IEEE [@1281]INPUT CH_A 3.007 IEEE [@1281] DCV AUTO 3.008 IEEE [@1281] [D2000]RDG?[I] 3.009 MATH MEM1 = .200 3.010 MATH MEM = MEM / M[1] 3.011 MEME 3.012 MEMC A 3% 0.000U 4.001 HEAD {} 4.002 HEAD {ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»} 4.003 HEAD {º LOAD REGULATION TEST º} 4.004 HEAD {ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ} 4.005 HEAD {}ÍÍ LOAD REGULATION TEST ÍÍ 4.006 JMP 5.002 4.007 EVAL 5.001 DISP Reconnect the lead to the 240-C input. 5.002 IEEE [@1281] INPUT FRONT 5.003 IEEE [@1281] DCV AUTO 5.004 IEEE [@1281] [D3000]RDG?[I] 5.005 MEME 5.006 DISP Disconnect one lead from the 240-C input. 5.007 IEEE [@1281] DCV AUTO,FAST_ON 5.008 IEEE [@1281] [D3000]RDG?[I] 5.009 MATH MEM = (MEM - MEM1) * 1000 5.010 MATH MEM1 = 0.00 5.011 MEME 5.012 MEMC mV 4.00U FULLÿtoÿNO 6.001 DISP Reconnect the lead to the 240-C input. 6.002 HEAD {} 6.003 HEAD {ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»} 6.004 HEAD {º LINE REGULATION TEST º} 6.005 HEAD {ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ} 6.006 HEAD {}ÍÍ LINE REGULATION TEST ÍÍ 6.007 JMP 7.001 6.008 EVAL 7.001 DISP Set the variac to 105 VAC. 7.002 IEEE [@1281] DCV AUTO,FAST_ON 7.003 IEEE [@1281] [D3000]RDG?[I] 7.004 MEME 7.005 DISP Set the variac to 125 VAC. 7.006 IEEE [@1281] DCV AUTO,FAST_ON 7.007 IEEE [@1281] [D3000]RDG?[I] 7.008 MATH MEM = (MEM - MEM1) * 1000 7.009 MATH MEM1 = 0.00 7.010 MEME 7.011 MEMC mV 4.00U 105ÿtoÿ125VAC 8.001 DISP Set the variac to 115 VAC. 8.002 HEAD {} 8.003 HEAD {ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»} 8.004 HEAD {º RIPPLE AND NOISE TEST º} 8.005 HEAD {ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ} 8.006 HEAD {}ÍÍ RIPPLE AND NOISE TEST ÍÍ 8.007 JMP 9.001 8.008 EVAL 9.001 IEEE [@1281]ACV AUTO 9.002 IEEE [@1281]RDG?[I][D2000]RDG?[I] 9.003 MATH MEM=(MEM*2.82)*1000 9.004 MATH MEM1 = 0.00 9.005 MEME 9.006 MEMC mVP-P +1.00U 10.001 HEAD 10.002 DISP Set the UUT front panel controls as follows: 10.002 DISP POWER ON/OFF ....................................... OFF 10.003 HEAD {} 10.004 DISP {ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»} 10.004 DISP {º THIS COMPLETES THE VERIFICATION º} 10.004 DISP {ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ} 10.005 END